Lifesize® Icon™ 400/450/600/800

Last Updated: Jan 25, 2023

Default values

This topic lists configuration preferences and their default values. To configure a preference using your system’s web interface, open a browser, enter the system’s IP address, and sign in. The default username and password are admin.

AppearanceH.323System
AudioMCUsLifesize UVC Transit
CallsNetworkUSB
Lifesize UVC ClearSeaRecord and StreamVideo
Date and TimeSecurityCamera Diagnostics
System Log LevelsSIP Registrar 1Auto Provisioning
DirectorySIP Registrar 2
Preferences > AppearanceDefault value
LanguageEnglish
Physical Display ArrangementDefault
Preferences > AudioDefault value
Video Call OutputHD Out
Voice Call OutputPhone
Icon 600 Only:
Analog Mic GainLine Level
Icon 800 Only:
Integrated Audio
(Available for Icon 600 from the command line)
Off
Active MicAuto
Audio MuteAll
Preferences > CallsDefault value
Auto AnswerDisabled
Auto Answer MuteEnabled
Auto BandwidthEnabled
Maximum Call Bandwidth6000 kb/s
Maximum Call Transmit Bandwidth6000 kb/s
Default Call Bandwidth1300 kb/s
Secondary StreamEnabled
Preferences > Lifesize UVC ClearSeaDefault value
Enable UVC ClearSeaDisabled
UVC ClearSea UsernameNo default
UVC ClearSea PasswordNo default
UVC ClearSea IP AddressNo default
Preferences > Date and TimeDefault value
System TimeGreenwich Mean Time (GMT) value
System DateGMT value
Time ZoneGMT
Clock Format12-Hour
NTP Server HostnameNo default
Preferences > System Log LevelsDefault value
Syslog ServerNo default
AudioDebug
CommunicationsDebug
DatabaseInformation
License ManagerInformation
System AdministrationInformation
System InformationInformation
System StatusInformation
TimerInformation
User InterfaceInformation
Video HardwareDebug
Video InInformation
Video OutInformation
Preferences > DirectoryDefault value
HostnameNo default
UsernameNo default
PasswordNo default
BaseNo default
PortNo default
EncryptionNone
Preferences > H.323Default value
Use H.323Enabled
NameNumber randomly generated by the system
ExtensionSame value as Name
Gatekeeper ModeOff
Available preferences with Gatekeeper ModeAuto
Gatekeeper IDNo default
Gatekeeper AuthenticationDisabled
Gatekeeper UsernameNo default
Gatekeeper PasswordNo default
Available preferences with Gatekeeper ModeManual or Manual H.460
Gatekeeper AddressNo default
Gatekeeper Port1719
Gatekeeper AuthenticationDisabled
Gatekeeper UsernameNo default
Gatekeeper PasswordNo default
Preferences > MCUsDefault value
Enable MCU IntegrationDisabled
IP AddressNo default
UsernameNo default
PasswordNo default
Preferences > NetworkDefault value
IP AddressNo default
Subnet MaskNo default
Use DHCPEnabled
Auto negotiate speed and duplex settingsEnabled
SpeedNo default
DuplexNo default
VLAN Tag0
Default GatewayNo default
DNS Server8.8.8.8
DNS DomainNo default
Search DomainsNo default
TCP and UDP Lowest Port Value60000
TCP and UDP Highest Port Value64999
Network QoSNone
Video Maximum Transmission Unit (MTU)1440
Static NATDisabled
NAT Public IP AddressNo default
802.1x AuthenticationDisabled
Preferences > Record and StreamDefault value
RecorderDisabled
Recorder HostnameNo default
Recorder Port443
Recording KeyNo default
Default Recording LayoutAll Callers
Preferences > SecurityDefault value
Enable SSH AccessEnabled
Enable Admin User SSH KeyDisabled
Enable Remote Management Over HTTPEnabled
509 AuthenticationDisabled
SIP SecurityOff
H.323 SecurityOff
Preferences > SIP Registrar 1Default value
Use SIPEnabled
SIP UsernameLifesize
Authorization UsernameNo default
Authorization PasswordNo default
SIP Server TypeAuto
SIP RegistrarDisabled
Registrar HostnameNo default
SIP RegistrationDirect
SIP ProxyDisabled
Proxy HostnameNo default
SIP SignalingAuto
Preferences > SIP Registrar 2Default value
Use SIPDisabled
SIP UsernameLifesize
Authorization UsernameNo default
Authorization PasswordNo default
SIP Server TypeAuto
SIP RegistrarDisabled
Registrar HostnameNo default
SIP RegistrationDirect
SIP ProxyDisabled
Proxy HostnameNo default
SIP SignalingAuto
Preferences > SystemDefault value
Auto Start PresentationEnabled
System NameConference Room
Preferences > Lifesize UVC TransitDefault value
UVC TransitDisabled
UVC Transit HostnameNo default
UVC Transit UsernameNo default
UVC Transit PasswordNo default
Enable for SIPDisabled
SIP UsernameNo default
Enable for H.323Disabled
H.323 ExtensionSame value as Preferences > H.323 > Extension
Preferences > USB 1 (and USB 2 for Icon 600 and 800 only)Default value
ShellNone
Speed115200 b/s
Flow ControlNo flow control
Preferences > VideoDefault value
Far Control of Near CameraEnabled
Far Set of Camera PresetsDisabled
Far Move to Camera PresetsEnabled
Presentation Video Bandwidth20%
Adaptive Motion ControlEnabled
HD Display ResolutionHighest resolution supported by the display
DVI Display ResolutionNo default
Enable CECDisabled
Enable SleepDisabled
HDMI DPMS ModeOff
DVI DPMS ModeOff
Diagnostics > CameraDefault value
IR ReceiverEnabled
Anti-FlickerAuto
Auto Exposure MethodFull-frame
Brightness0
Auto FocusEnabled
White BalanceAuto
Lock camera positionDisabled
Maintenance > Auto ProvisioningDefault value
Auto Provisioning ServerNo default